  • Ken Sowards
    Post count: 0

    I cannot use the shunt on the negative side. Is there any other option?
    I can’t separate the grounds.

    Drok
    Keymaster
    Post count: 2971

    Hello Ken Sowards,
    Thanks for writing in.
    Would you please tell us what the problem is?
    In order not to damage the meter, DC power – should go through the shunt to connect the meter -.
    Best regards.

    Ken Sowards
    Post count: 0

    Need to use positive power wire not able to use negative wire for the shunt as it shows on the meter I have several ground cables not just one this is on a boat

    Drok
    Keymaster
    Post count: 2971

    Hello Ken Sowards,
    If you connect the shunt on the positive terminal, the meter”-” will be connect directly to the power supply”-“. Is it right? In that case, it is likely to burn the meter.
    Bet regards.

    Ken Sowards
    Post count: 0

    Yes the shunt would be in line on positive cable

    Drok
    Keymaster
    Post count: 2971

    Hello Ken Sowards,
    As what we said previously, we are sorry the shunt can’t be hooked to the positive terminal. That will cause that the meter”-” is connected directly to the power supply”-“. Meter may be burned.
    Or did you have different idea? would you please share us how do you going to hooked it up? It would be appreciated if you can draw a simple diagram.
    Best regards.

    John Darbo
    Post count: 0

    Ken,

    You have no alternative but to use the negative side, but you can do it.

    You can attached one end of the shunt to the battery’s negative terminal, and then collect (consolidate) all the negative lines to the other end of the shunt.

     

    Use this to attach the shunt to your negative battery postz;

    https://www.amazon.com/East-Penn-01056-Battery-Terminal/dp/B000CGFOAI

    Then simply use the supplied bolt on the other end of the shunt to attached  your ground wires.

    I had to do it on my RV.

    Cheers,

    John