    Post count: 0

    Hello, I am very interested in your products however I need to know the actual ripple measurements. I could only find a reference on this website of ripple being “as low as 50mV”. Do you have actual measurement data?

    In particular, I need to the know the ripple for these two products:

    NC Step Down Voltage Regulator DC-DC 6-40V to 0-38V 8A Adjustable

    24V to 12V 5V NC Buck Module 5-32V to 0-30.0V Adjustable Digital Control Voltage Regulator 5A Constant Volts / Current with Ammeter Voltmeter Dual LED Display

    Thank you.

    Drok
    Keymaster
    Post count: 2971

    Hi Fred, connecting with different load, the ripple are different.
    About the 8A NC Step Down Voltage Regulator, no load ripple is 20mv, peak ripple is 100mv
    And about the 5A Constant NC Buck Module, the ripple is -40mV ~ 50mV.