Home › Forums › Any Other Products › Programmable Cycle Relay Module 200088 Timer Issue
-
AuthorPosts
-
JustinJune 28, 2019 at 5:23 amPost count: 0
I purchased a programmable timer relay module (PN 200088) on Amazon. All of the functions appear to work as expected; however, the timer is only accurate in modes 17 and 18. In all other modes, T1 and T2 count down extremely fast (9990 = approximately 25 seconds). In some modes, T1 counts down very quickly and T2 counts down very slowly (T2 = 5 = 16 seconds). I have tried all different settings with and without the decimal point and all different modes. Only mode 17 and mode 18 function normally. Any options?
Thanks for the help,
Justin
JustinJune 28, 2019 at 2:28 pmPost count: 0Hello Justin,
Thanks for your information.
After checking, it should be normal. The problem is caused by NX setting. Please refer to below instruction.
For mode 7, 8, 17, and 18, NX means the number of cycle. But for 1-6 and 11-16, it is a unit of time.
For example, you want to set T1 as 10 seconds. If NX is set as 1 second, you can set T1 as 10.
However, if NX is 2, T1 should be 5. The LED will flash 5 times instead of 10. It seems the frequency is different, actually time length is the same. You can check the time with other device. For any questions, please kindly contact us.
Best regards.
- This reply was modified 5 years, 4 months ago by Drok.
-