ApolloJune 23, 2019 at 10:22 pmPost count: 0
I purchased a “<span style=”display: inline !important; float: none; background-color: #ffffff; color: #111111; font-family: ‘Amazon Ember’,Arial,sans-serif; font-size: 21px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; line-height: 1.3; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;”>DROK 200202 Dual-MOS Cycle Time Delay Module, DC 5-36V On-Off Delay Timer Switch, 15A 400W High Power Digital Delay”. I have powered it up and configured it successfully, but I can not get it to trigger. There is a statement on the instruction manual that states “<span style=”color: #007000; font-family: ‘Amazon Ember’,Arial,sans-serif; font-size: x-large;”> the main interface will display “000” (no decimal point); in the status that the relay is working, there will be a decimal point</span>”. I csn not get it to show the decimal. I assume this is why it will not trigger. I am shorting common ground to trigger. Also – is there a way to do the same for the output. I’d just need to close a switch on the output to trigger a camera. </span>
Thanks
Apollo
ApolloJune 23, 2019 at 10:23 pmPost count: 0I purchased a “DROK 200202 Dual-MOS Cycle Time Delay Module, DC 5-36V On-Off Delay Timer Switch, 15A 400W High Power Digital Delay”. I have powered it up and configured it successfully, but I can not get it to trigger. There is a statement on the instruction manual that states “the main interface will display “000” (no decimal point); in the status that the relay is working, there will be a decimal point”. I can not get it to show the decimal. I assume this is why it will not trigger. I am shorting common ground to trigger. Also – is there a way to do the same for the output. I’d just need to close a switch on the output to trigger a camera.
Thanks
Apollo
ApolloJune 24, 2019 at 2:24 pmPost count: 0I tried various ones. I tried P1.1 and set OP to 5 seconds. I also tried P3.2 and set OP to 5 and CL to 15. When I do P3.2, it does start the countdown on power up, but I can’t get the other programs to trigger. Do I need the decimal place to be showing (0000.)?
Also – Is there a way to use this as a dry contact on the output? I have not hooked up the output yet.
thanks
Hello Apollo,
It doesn’t matter if you connect load to output.
We wonder whether you connect trigger siganl. Only P3.2 doesn’t require trigger signal.
The other programs can’t work without trigger signal. For example, P1: when there is trigger signal, the relay close for some time, and then open.
Best regards.
-