    New WLS-PVA200.
    Using two wire hookup method.  I have additional parameters in setup screens like “CV”, etc. that are not mentioned in documentation.  Whatever is set to “CV” is what voltage is displayed on status screen, and not the live, dynamic voltage.  Need this fixed or must return to Amazon.

    Scott
    Post count: 0

    Please disregard my previous post.  For everyone who has this latest firmware on WLS-PVA200 and similar models, only set AH and FV.  For all other parameters, leave at 0000.