    Hello Joseph DeVecchio,

    You can extend lead wire as need, it doesn’t affect measurement. If you want to monitor the battery temperature, just put the sensor close to battery.

    Best regards.

    Drok
    Keymaster
    Post count: 2971
    in reply to: bucks in parallel #92805

    Hello

    Do you mean the output port of buck converters are connected in parallel? We don’t recommend parallel connection. It may be easy to damage some of them.

    Best regards,

     

    Drok
    Keymaster
    Post count: 2971

    Hello Gerald Lang,

    We can’t confirm which item it is, would you like to offer product link? If it is  buck converter only,  it can’t step up voltage from 12v to 20v.

    Best regards

     

    Drok
    Keymaster
    Post count: 2971
    in reply to: Meter Availability #92153

    Hello,

    As they are not hot sale  items, there are no ready-made stock. We can prepare items after paying.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello,

    display color can’t be changed.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello Rex,

    Manufacturer said not only the mosfet, power supply chip, voltage converter chip and capacitance should also damage.

    You still need to check other parts. In that case, it is better to replace item directly.

    Beset regards,

    DROK

    Drok
    Keymaster
    Post count: 2971

    Hello Rex,

    We are waiting for response from  manufacturer. Please kindly wait a monent.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello,

    About custom item, we need to check with factory.  Please confirm custom details firstly.

    1.With trigger signal, there is  0.1 to 99.9 seconds  delay time before turning on relay. Do you hope the delay time is adjusted by user?

    2. Cycle times is once, should we save the setting for cycle times?

    For more detail, would you pleaes send email to service@droking.com?

    Best regards,

    DROK

     

    Drok
    Keymaster
    Post count: 2971

    Hello Michael,

    Did you program AH and FU parameters?  Both are necessary setting. And after setting parameters, it can’t show correct reading at once.  Please fully charged battery.

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello,

    Sorry, that is not sold by us, we can’t confirm how it is. You may check if there are similar item in our store, below are two for your reference.

    #200119,   https://www.amazon.com/dp/B017GZW0WW?ref=myi_title_dp

    #200399,  https://www.amazon.com/dp/B07DFT2WDS?ref=myi_title_dp

    Drok
    Keymaster
    Post count: 2971

    Hello Kristopher Cox,

    Does it triggered by signal? And how large is the load power you need to control? We can make some changes based on original item. Is there any product meet your need?

    Drok
    Keymaster
    Post count: 2971

    Hello,

    Please notice only KWH parameter can be zero. Just hold the upper button 3 seconds to reset it.

    “FFF” means current has been over the range 200A.

    Best regards,

    DROK

    Drok
    Keymaster
    Post count: 2971

    Hello,

    There is QR code on measuring module, you can scan it to download APP.

    Or please click this link, http://68.168.132.244/app/KG/kg.html

    Best regards.

    Drok
    Keymaster
    Post count: 2971

    Hello,

    Here is pdf manual  from manufacturer, our own manual will be updated later.

    https://www.droking.com/cs/wp-content/uploads/2022/04/200617、200618_EN_manual.pdf

    Drok
    Keymaster
    Post count: 2971

    Hello,

    Version has been updated to SG-03.   To save the setting after power off, please enable “P007”

    Here is manual, https://www.droking.com/cs/wp-content/uploads/2022/04/300482.pdf